| IEC
61000-1 General |
|
IEC
61000-1-1
(1992-05) |
Electromagnetic compatibility (EMC)
- Part 1: General
- Section 1: Application and interpretation of fundamental definitions and
terms |
| IEC
61000-2 Enviroment |
|
IEC 61000-2-1
(1990-05) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 1: Description of the environment
- Electromagnetic environment for low-frequency conducted disturbances and
signalling in public power supply systems |
|
IEC
61000-2-2
(1990-05) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 2: Compatibility levels for low-frequency conducted disturbances
and signalling in public low-voltage power supply systems |
|
IEC/TR3
61000-2-3 (1992-10) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 3: Description of the environment - Radiated and non-network-frequency-related
conducted phenomena |
|
IEC
61000-2-4
(1994-02) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 4: Compatibility levels in industrial plants for low-frequency
conducted disturbances |
|
IEC/TR2
61000-2-5 (1995-09) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 5: Classification of electromagnetic environments. Basic EMC publication |
|
IEC/TR3
61000-2-6 (1995-09) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 6: Assessment of the emission levels in the power supply of industrial
plants as regards low-frequency conducted disturbances |
|
IEC/TR3
61000-2-7 (1998-01 |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 7: Low frequency magnetic fields in various environments |
|
IEC
61000-2-9
(1996-02) |
Electromagnetic compatibility (EMC)
- Part 2: Environment
- Section 9: Description of HEMP environment - Radiated disturbance. Basic
EMC publication |
| IEC
61000-3 Limits |
| IEC/TR 61000-3-1 |
Electromagnetic compatibility (EMC)
- Part 3-1: Limits - Overview of emission standards and guides - Technical
Report |
|
IEC
61000-3-2
(1995-03) |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 2: Limits for harmonic current emissions (equipment input current
<= 16 per phase). |
|
IEC
61000-3-2
(1998-04) Ed. 1.2 Consolidated Edition |
Electromagnetic compatibility (EMC)
- Part 3-2: Limits
- Limits for harmonic current emissions (equipment input current <=16
per phase). |
IEC 61000-3-2
(2000-08)
Ed. 2.0 |
Electromagnetic compatibility (EMC) - Part 3-2:
Limits - Limits for harmonic current emissions (equipment input current
<= 16 A per phase). Specifies limits for harmonic current
emissions applicable to electrical and electronic equipment having an input
current up to and including 16 A per phase, and intended to be connected
to public low-voltage distribution systems. The tests according to this
standard are type tests. Test conditions for particular equipment are given
in annex C. For systems with nominal voltages less than 220 V (line to neutral),
the limits have not yet been considered. |
|
IEC 61000-3-2-am1
(1997-09) |
Amendment No.1 |
| EN 61000-3-2:1995
DOW 2001-01-01 |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 2: Limits for harmonic current emissions (equipment input current
up to and including 16 A per phase)
Amendment A1:1998 to EN 61000-3-2:1995 / IEC 61000-3-2:1995 /A1:1997
Amendment A2:1998 to EN 61000-3-2:1995 / IEC 61000-3-2:1995 /A2:1998 |
| EN 61000-3-2-am1
2001-08 Ed2.0 |
Electromagnetic compatibility (EMC)
- Part 3-2: Limits
- Limits for harmonic current emissions (equipment input current <=16
A per phase) |
EN 61000-3-2
2001-10 Consolidated Ed2.1 |
- Electromagnetic compatibility (EMC)
- Part 3-2: Limits
- Limits for harmonic current emissions (equipment input current <= 16A
per phase) |
|
IEC
61000-3-3:1994 |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 3: Limitation of voltage fluctuations and flicker in low-voltage
supply systems for equipment with rated current <= 16 A. |
| EN 61000-3-3:1995 DOW 2001-01-01
|
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 3: Limitation of voltage fluctuations and flicker in low-voltage
supply systems for equipment with rated current up to and including 16 A
See also EN60555-3:1987 |
| IEC 61000-3-4 |
Electromagnetic compatibility (EMC)
- Part 3: Limits
-Section 4: Limitation of emission of harmonic currents in low-voltage power
supply systems for equipment with rated current greater than 16 A |
|
IEC/TR2
61000-3-5 (1994-12) |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 5: Limitation of voltage fluctuations and flicker in low-voltage
power supply systems for equipment with rated current greater than 16 A |
|
IEC/TR3
61000-3-6 (1996-10) |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 6: Assessment of emission limits for distorting loads in MV and
HV power systems - Basic EMC publication |
|
IEC/TR3
61000-3-7 (1996-11) |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 7: Assessment of emission limits for fluctuating loads in MV and
HV power systems - Basic EMC publication |
|
IEC
61000-3-8
(1997-09) |
Electromagnetic compatibility (EMC)
- Part 3: Limits
- Section 8: Signalling on low-voltage electrical installations - Emission
levels, frequency bands and electromagnetic disturbance levels |
| IEC 61000-3-9 |
Electromagnetic compatibility (EMC)
- Part 3 Limits
-Section 9: Limits for interharmonic current emissions (equipment with input
power <= 16 A per phase and prone to produce interharmonics by desing)
|
| IEC 61000-3-11
(2000-08) |
Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation
of voltage changes, voltage fluctuations and flicker in public low-voltage
supply systems - Equipment with rated current <= 75 A and subjet to conditional
connection This part of IEC 61000 is concerned with
the emission of voltage changes, voltage fluctuations and flicker produced
by equipment and impressed on the public low-voltage supply system. It specifies
the limits of voltage changes produced by equipment tested under specified
conditions. Equipment tests made in accordance with this part of IEC 61000
are type tests. |
| IEC
61000-4 Testing and measurement techniques |
|
IEC
61000-4-1
(1992-12) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 1: Overview of immunity tests. Basic EMC Publication |
|
IEC
61000-4-2
(1995-01) |
Electromagnetic
compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 2: Electrostatic discharge immunity test Basic EMC Publication |
| EN 61000-4-2 |
Electromagnetic compatibility
(EMC)
- Part 4: Testing and measurement techniques
- Section 2: Electrostatic discharge immunity test |
|
IEC
61000-4-2-am1 (1998-01) |
Amendment 1 to IEC 61000-4-2 (First edition) |
|
IEC
61000-4-3
(1995-03) |
Electromagnetic
compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 3: Radiated radio-frequency, electromagnetic fields immunity test |
| EN 61000-4-3 |
Electromagnetic compatibility
(EMC)
- Part 4: Testing and measurement techniques
- Section 3: Radiated radio-frequency, electromagnetic fields
- Immunity test |
| ENV 50 204 |
Radiated electromagnetic fields
from digital radio telephones, Immunity test |
| ENV 50 140 |
Electromagnetic compatibility
- Basic immunity standard
- Radiated radio-frequency, electromagnetic fields immunity test |
|
IEC
61000-4-4
(1995-01) |
Electromagnetic
compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 4: Electrical fast transient/ burst immunity test |
| IEC 60255-22-4
|
Electrical relays
- Part 22: Electrical disturbance tests for measuring relays and protection
equipment
- Section 4: Fast transient disturbance test. |
| EN 61000-4-4 |
Electromagnetic compatibility
(EMC)
- Part 4: Testing and measurement techniques
- Section 4: Electrical fast transient/ burst immunity test |
|
IEC
61000-4-5
(1995-03) |
Electromagnetic
compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 5: Surge immunity test |
| EN 61000-4-5 |
Electromagnetic compatibility
(EMC)
- Part 4: Testing and measurement techniques
- Section 5: Surge immunity test |
| ENV 50 142 |
Electromagnetic compatibility
- Basic immunity standard
- Surge immunity test |
|
IEC
61000-4-6
(1996-04) |
Electromagnetic
compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 6: Immunity to conducted disturbances, induced by radio-frequency
fields |
| EN 61000-4-6 |
Electromagnetic compatibility
(EMC)
- Part 4: Testing and measurement techniques
- Section 6: Immunity to conducted disturbances, induced by radio-frequency
fields |
| ENV 50141 |
Electromagnetic compatibility
- Basic immunity standard
- Conducted disturbancces induced by radio-frequency fields
- Immunity test |
|
IEC
61000-4-7
(1991-08) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 7: General guide on harmonics and interharmonics measurements
and instrumentation, for power supply systems and equipment connected thereto |
|
IEC
61000-4-8
(1993-06) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 8: Power frequency magnetic field immunity test. Basic EMC Publication |
|
IEC
61000-4-9
(1993-06) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 9: Pulse magnetic field immunity test. Basic EMC Publication |
|
IEC
61000-4-10
(1993-06) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 10: Damped oscillatory magnetic field immunity test. Basic EMC
Publication |
|
IEC
61000-4-11
(1994-06) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measuring techniques
- Section 11: Voltage dips, short interruptions and voltage variations immunity
tests |
|
IEC
61000-4-12
(1995-05 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 12: Oscillatory waves immunity test. Basic EMC Publication |
| IEC 61000-4-13 |
Electromagnetic Compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 13: Test for immunity to harmonics and interharmonics including
mains signalling at a.c. power port
- Basic EMC Publication |
IEC 61000-4-14
(1999-02) |
Electromagnetic compatibility (EMC)
- Part 4-14: Testing and measurement techniques
- Voltage fluctuations, immunity test
Testing and measurement techniques - Voltage
fluctuation immunity test" Considers immunity tests for electrical
and/or electronic equipment in their electromagnetic environment. Only
conducted phenomena are considered including tests for equipment connected
to public and industrial power supply networks.
Establishes a reference for evaluating the
immunity of equipment when subjected to positive and negative low amplitude
voltage fluctuation (excluding flicker, a physiological phenomenon due
to lighting luminance fluctuations). |
|
IEC
61000-4-15
(1997-11) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 15: Flickermeter - Functional and design specifications |
IEC 61000-4-16
(1998-01) |
Electromagnetic compatibility (EMC)
- Part 4-16: Testing and measurement techniques
- Test for immunity to conducted, common mode disturbances in the frequency
range 0 Hz to 150 kHz |
| IEC 61000-4-17 |
Electromagnetic compatibility (EMC)
- Part 4-17: testing and measuring techniques
- Ripple on d.c. input power port, immunity test |
| IEC 61000-4-20 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 20: TEM cells. Basic EMC Publication |
| IEC 61000-4-21 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 21: Reverberation chambers |
| IEC 61000-4-22 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 22: Guide on measurement methods for electromagnetic phenomena
|
| IEC 61000-4-23 |
Test methods for protective devices for HEMP and other radiated disturbance.
Basic EMC publication |
|
IEC
61000-4-24
(1997-02) |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 24: Test methods for protective devices for HEMP conducted disturbance
- Basic EMC Publication |
| IEC 61000-4-25 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 25: HEMP requirements and test methods for equipment and systems.
Basic EMC Publication |
| IEC 61000-4-27
(2000-08) |
Electromagnetic compatibility (EMC) - Part 4-27: Testing and measurement
techniques - Unbalance, immunity test Considers immunity
tests for electric and/or electronic equipment (apparatus and system) in
its electromagnetic environment. Only conducted phenomena are considered,
including immunity tests for equipment connected to public and industrial
networks. Establishes a reference for evaluating the immunity of electrical
and electronic equipment when subjected to unbalanced power supply voltage.
Applies to 50 Hz/60 Hz three-phase powered electrical and/or electronic
equipment with rated line current up to 16 A per phase. |
| IEC 61000-4-28 |
Electromagnetic compatibility (EMC)
- Part 4-28: Testing and measurement techniques
- Variation of power frequency, immunity test |
| IEC 61000-4-29
(2000-08) |
Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement
techniques - Voltage dips, short interruptions and voltage variations on
d.c. input power port immunity tests Establishes a
common and reproducible basis for testing electrical and electronic equipment
when subjected to voltage dips, short interruptions or voltage variations
on d.c. power ports. This standard defines: - the range of test levels;
- the test generator; - the test set-up; - the test procedure. |
| IEC 61000-4-30 f2 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 30: Measurements of power quality parameters. - Basic EMC Publication
|
| IEC 61000-4-30 f1 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 30: Measurement of power quality parameters. - Basic EMC Publication
|
| IEC 61000-4-31 |
Electromagnetic compatibility (EMC)
- Part 4: Testing and measurement techniques
- Section 31: Measurements in the frequency range 2 kHz to 9 kHz. Basic
EMC standard |
| IEC
61000-5 Installation and mitigation guidelines |
|
IEC/TR3
61000-5-1 (1996-12) |
Electromagnetic compatibility (EMC)
- Part 5: Installation and mitigation guidelines
- Section 1: General considerations
- Basic EMC publication |
|
IEC/TR3
61000-5-2 (1997-11) |
Electromagnetic compatibility (EMC)
- Part 5: Installation and mitigation guidelines
- Section 2: Earthing and cabling |
| IEC 61000-5-3 |
Electromagnetic compatibility (EMC)
- Part 5
- Section 3: Installation and mitigation guidelines - HEMP protection concepts |
|
IEC/TR2
61000-5-4 (1996-08) |
Electromagnetic compatibility (EMC)
- Part 5: Installation and mitigation guidelines
- Section 4: Immunity to HEMP - Specifications for protective devices against
HEMP radiated disturbance. Basic EMC Publication |
|
IEC
61000-5-5
(1996-02) |
Electromagnetic compatibility (EMC)
- Part 5: Installation and mitigation guidelines
- Section 5: Specification of protective devices for HEMP conducted disturbance.
Basic EMC Publication |
| IEC/TR 61000-5-6 |
Electromagnetic compatibility (EMC)
- Part 5: Installation and mitigation guidelines
- Section 6: Mitigation of external EM influences |
| IEC
61000-6 Generic standards |
|
IEC
61000-6-1 |
Electromagnetic compatibility (EMC)
- Part 6: Generic standards
- Section 1: Immunity for residential, commercial and light-industrial environments |
| IEC 61000-6-2 |
Electromagnetic compatibility (EMC)
- Part 6: Generic standards
- Section 2: Generic immunity standard for industrial environments |
| IEC 61000-6-3
|
Electromagnetic compatibility (EMC)
- Part 6: Generic standards
- Section 3: Emission standard for residential, commercial and light-industrial
environments |
|
IEC
61000-6-4
|
Electromagnetic compatibility (EMC)
- Part 6: Generic standards
- Section 4: Emission standard for industrial environments |
| IEC/TS 61000-6-5 |
Electromagnetic compatibility (EMC)
- Part 6-5: Generic standards
- Immunity of apparatus for generating stations and high-voltage substations
|
| CISPR
Standarder |
|
CISPR
10
(1992-09) |
Organization, rules and procedures of the CISPR. |
|
CISPR
10-am1
(1995-04) |
Amendment No. 1 |
|
CISPR
11
(1997-12) |
Radio interference
- Limits and methods of measurement of electromagnetic disturbance characteristics
of industrial, scientific and medical (ISM) radio-frequency equipment |
| EN 55011:1991
DOW 1998-01-01 |
Radio interference
- Limits and methods of measurement of radio disturbance characteristics
of industrial, scientific and medical (ISM) radio-frequency equipment
Amendment A2:1996 to EN 55011:1991
Amendment A1:1997 to EN 55011:1991
|
| EN 55011:1998
DOW 2001-01-01 |
Industrial, scientific and medical (ISM) radio-frequency
equipment
- Radio disturbance characteristics
- Limits and methods of measurement |
|
CISPR
12 ed5 |
Vehicles, motorboats and spark-ignited engine-driven
devices - Radio disturbance characteristics -
Limits and methods of measurement. |
|
CISPR
13
(1996-09) |
Limits and method of measurement of radio interference
characteristic of sound and television broadcast receivers and associated
equipment. |
| EN 55013:1990
DOW 1998-12-31 and 1999-06-01 |
Limits and methods of measurement of radio disturbance
characteristics of broadcast receivers and associated equipment
Amendment A12:1994 to EN 55013:1990
Amendment A13:1996 to EN 55013:1990 |
|
CISPR
14-1
(1993-02) |
Limits and methods of measurement of radio disturbance
characteristics of electrical motor-operated and thermal appliances for
household and similar purposes, electric tools and electric apparatus. |
|
CISPR
14-1-am1
(1996-09) |
Amendment No. 1 |
|
CISPR
14-2
(1997-02) |
Electromagnetic compatibility - Requirements for
household appliances, electric tools and similar apparatus -
Part 2: Immunity - Product family standard. |
| EN 55014-1:1993
DOW 1995-12-31 and 1998-01-01 |
Electromagnetic compatibility
- Requirements for household appliances, electric tools and similar apparatus
- Part 1: Emission
- Product family standard
Amendment A1:1997 to EN 55014-1:1993 |
| EN 55014-2:1997
DOW 2001-01-01 |
Electromagnetic compatibility
- Requirements for household appliances, electric tools and similar apparatus
- Part 2: Immunity
- Product family standard |
|
CISPR
15
(1996-03)
(2000-08 Ed. 2.0) |
Limits and methods of measurement of radio disturbance
characteristics of electrical lighting and similar equipment
Applies to the emission (radiated and conducted) of radiofrequency disturbances
from: - all lighting equipment with a primary function of generating and/or
distributing light intended for illumination purposes,and intended either
for connection to the low voltage electricity supply or for battery operation;
- the lighting part of multi-function equipment where one of the primary
functions of this is illumination;
- independent auxiliaries exclusively for use with lighting equipment;
- UV and IR radiation equipment;
- neon advertising signs;
- street/flood lighting intended for outdoor use;
- transport lighting (installed in buses and trains).
The frequency range covered is 9 kHz to 400 GHz. |
|
CISPR
15-am1
(1997-06) |
Amendment No. 1 |
|
CISPR
16-1
(1998-01) Ed. 1.1 Consolidated Edition |
Specification for radio disturbance and immunity
measuring apparatus and methods -
Part 1: Radio disturbance and immunity measuring apparatus. |
|
CISPR
16-2
(1996-11) |
Specification for radio disturbance and immunity
measuring apparatus and methods -
Part 2: Methods of measurement of disturbances and immunity. |
CISPR 16-2
Amd.2 f4 |
- Concept EMC Standard
- Anechoic chambers
- Emission measurements in fully anechoic chambers |
CISPR 16-3
Amd.1 f2 |
Determining EMC compliance uncertainty |
|
CISPR
17
(1981-01) |
Methods of measurement of the suppression characteristics
of passive radio interference filters and suppression components Radio interference
characteristics of overhead power lines and high-voltage equipment.
Part 1: Description of phenomena. |
|
CISPR
18-1
(1982-01) |
Radio interference characteristics of overhead
power lines and high-voltage equipment.
Part 1: Description of phenomena. |
|
CISPR
18-2
(1986-10) |
Radio interference characteristics of overhead
power lines and high-voltage equipment.
Part 2: Methods of measurement and procedure for determining limits. |
|
CISPR
18-2-am1
(1993-04) |
Amendment No. 1 |
|
CISPR
18-2-am2
(1996-12) |
Amendment No. 2 |
|
CISPR
18-3
(1986-09) |
Radio interference characteristics of overhead
power lines and high-voltage equipment.
Part 3: Code of practice for minimizing the generation of radio noise. |
|
CISPR
18-3-am1
(1996-05) |
Amendment No. 1 to IEC 18-3 |
|
CISPR
19
(1983-01) |
Guidance on the use of the substitution method
for measurements of radiation from microwave ovens for frequencies above
1 GHz. |
|
CISPR
20
(1996-02) |
Limits and methods of measurement of immunity
characteristics of sound and television broadcast receivers and associated
equipment. |
|
CISPR
20-am1
(1997-02) |
Amendment No. 1 |
|
CISPR
20-am2
(1997-07) |
Amendment No. 2 |
| EN55020 |
EN 55020:1994, "Radiostörningar - Immunitet mot
radiostörningar hos
rundradiomottagare, tv-mottagare och tillhörande utrustnigar"
(ersatte
1988 års utgåva redan 1998-12-31) med tilläggen A11:1996
(övergångsdatum 1999-06-01) samt A13:1999 och A14:1999 (övergångsdatum
2001-08-01). A12:1999 är även listad, men behöver inte tillämpas
förrän 2002-08-01, men alla de övriga gäller utan alternativ. |
|
CISPR
21
(1985-01 |
Interference to mobile radiocommunications in
the presence of impulsive noise; methods of judging degradation and measures
to improve performance. |
|
CISPR
22
(1997-11) |
Radio interference
- Limits and methods of measurement of electromagnetic disturbance characteristics
of information technology equipment (ITE) |
EN 55022:1998
fr o m 2003-08-01 |
Radio interference
- Limits and methods of measurement
of electromagnetic disturbance characteristics of information technology
equipment (ITE) |
EN 55022:A1:2000
fr o m 2003-08-01 |
Radio interference
- Limits and methods of measurement
of electromagnetic disturbance characteristics of information technology
equipment (ITE) |
|
CISPR
23
(1987-12 |
Determination of limits for industrial, scientific
and medical equipment. |
|
CISPR
24
(1997-09) |
Information technology equipment
- Immunity characteristics
- Limits and methods of measurement. |
| EN 55024 |
Information technology equipment "ITE"
- Immunity characteristics
- Limits and methods of measurement. |
|
CISPR
25
(1995-11) |
Limits and methods of measurement of radio disturbance
characteristics for the protection of receivers used on board vehicles. |
|
CISPR/TR3
28
(1997-04) |
Industrial, scientific and medical equipment (ISM)
- Guidelines for emission levels within the bands designated by the ITU. |
| CISPR 29-1 |
EMC requirements for toys product family standard
- Part 1: Emission |
|
CISPR
1000-6-3
(1996-12) |
Electromagnetic compatibility (EMC)
- Part 6: Generic standards
- Section 3: Emission standard for residential, commercial and light-industrial
environments. |
OBS Denna lista är inte komplet utan du måste söka i europeiska
tidningen OJ vilka som gäller för tillfället.
| EN 55103-2 |
Requirements for Audio, Vidio, audio visual and entertainment lighting
control apperatus for professional use. |
IEC 60118-13
(1997-09) |
Hearing aids
- Part 13: Electromagnetic compatibility (EMC) |
| IEC 60034-1 f2 |
Amendment to IEC 60034-1
- Clause 12: Electromagnetic compatibility (EMC) |
| IEC 60076-1 Amd.1 |
Amendment to IEC 60076-1
- Clause 11: Electromagnetic compatibility (EMC) |
| IEC 60099-1 Amd.1 f3 |
Amendment to IEC 60099-1
- EMC |
| IEC 60099-4 Amd.3 f2 |
Amendment to IEC 60099-4
- EMC |
| EN 50199:1995 DOW 1996-07-01 |
Electromagnetic compatibility (EMC) - Product standard for arc welding
equipment |
| EN 60521 |
Class 0.5, 1 and 2 alternating current Watt-hour meters. |
| 60601-1-2 |
"Medical electrical equipment -
Part 1-2: General requirements for safety - Collateral standard:
Electromagnetic compatibility - Requirements and tests"
|
| IEC 60694 Amd.1 f4 |
Amendment to IEC 60694 : Common specifications for high-voltage switchgear
and controlgeard standards
- EMC tests |
EN 60730-2-1
IEC 730-2-1 |
Specification for automatic electrical controls for household and similar
use
Particular requirements - Electrical controls for electrical household appliances. |
| EN 60870-2-1 |
Telecontrol equipment and systems - operating conditions power supply
and EMC. |
| IEC 60921 f1 |
EMC Immunity requirements |
| IEC 60925 Amd.2 |
EMC - Immunity requirements |
IEC 947-5-2
EN 60947-5-2 |
Low voltage switchgear and control gear - Contactors and motors starters
-
Control circuit devices and switching elements - proximity switches. |
| IEC 60974-10 |
Arc welding equipment
- Part 10: EMC requirements |
| IEC 61095 Amd.1 |
Electromechanical contactors for household use - Addition of EMC requirements |
| IEC 61156-2 Amd.1 f1 |
EMC - Method of measurement (Amendment to Documents 46C(Sec.)196, 198,
200) |
| EN 61204-3 |
Low-voltage power supplies, d.c. output
- Part 3: Product EMC standard
(strömförsörjningsdon med likströmsutgång) |
| IEC 61547 Amd.1 |
Amendment 1 to IEC 61547: Equipment for general lighting purposes
- EMC immunity requirements |
IEC 61326-1
(1997-03) |
Electrical equipment for measurement, control and laboratory use
- EMC requirements
- Part 1: General requirements
Specifies the minimum EMC requirements for electrical
equipment intended for professional, industrial processes and educational
use operating from a supply of less than 1000 V a.c. or 15000 V d.c. |
IEC 61326-1
(1998-08) |
IEC 61326-1 (1998-08) Ed. 1.1 Consolidated Edition
Electrical equipment for measurement, control and laboratory use
- EMC requirements |
| EN 61326-1:1997 DOW 2001-07-01 |
Relevant generic standard
- Electrical equipment for measurement, control and laboratory use
- EMC requirements Amendment A1:1998 to EN 61326-1:1997 |
IEC 61543
(1995-04) |
Residual current-operated protective devices (RCDs) for household and
similar use
- Electromagnetic compatibility |
IEC 61547
(1995-09) |
Equipment for general lighting purposes
- EMC immunity requirements |
IEC 61800-3
(1996-06)
"EN61800-3" |
Adjustable speed electrical power drive systems
- Part 3: EMC product standard including specific test methods |
| IEC/TR 61844 |
Guide for EMC screening optimization of braided coaxial cables |
| IEC 61867 |
Electrical accessories for household and similar use
- Electromagnetic compatibility (EMC) |
IEC/TR3 61917
(1998-06) |
Cables, cable assemblies and connectors
- Introduction to electromagnetic (EMC) screening measurements |
| IEC 62040-2 |
Uninterruptible power systems (UPS): Electromagnetic compatibility - (EMC)
requirements According to the scope of this
publication, it applies to single UPS units or UPS systems comprising
a number of interconnected UPS and associated control/switchgear forming
a single power system, intended to be installed in any operator
accessible area or in separated electrical locations, connected to either
industrial or public low voltage supply networks. This product EMC standard
takes precedence over all aspects of the generic standards, and no additional
testing is necessary. |
| IEC 62041 |
Small power transformers, power supply units and similar devices - EMC
requirements |